FE 0212 IR 00
Drawing
Hydraulic symbol
Pressure drop
www.eltfluid.com
For general conditions and terms of use see page S.035.
This document is Elt Fluid property and therefore data or
technical specification can not be reproduced.
Eltfluid also reserves the right to make modifications in
any case the above data.
Oil viscosity: 32cSt/200 Fluid temperature: 40° C
1
2
1.
E12N-21
1,05
26,7
0,33
8,5
2,57
65,3
2,95
75
2,25
57,2
0,17
R4,25
2,56
65
0,16
4,1
0,23
5,9
2,95
75
1,13
28,7
0,87
22,2
1,81
46
2,59
65,8
Hex.
1,26
32
1-1/16" -12 UNF-2A
0,93
23,5
1,39
35,4
1
2
1,42
36
2,95
75
1,57
40
Foglio1
Foglio
Note:
A3
Questo documento è di propietà Eltfluid non è quindi possibile riprodurre dati o specifiche senza il suo consenso scritto.Eltfluid si riserva anche il diritto di poter in qualunque caso apportare modifiche ai dati sopra citati.
La società propietaria tutela i propri diritti a rigore di legge.
+/- 0.5
+/- 0.3
+/- 0.2
+/- 0.1
>120 <=400
>30 <=120
>6 <=30
Fino a 6
Scostamenti limite ammessi per dimensioni
lineari, esclusi smussi e raccordi per
eliminazione spigoli.
Valori in mm
Data:
-
1:1
-
- -
0
Scostamenti limite per dim.lineari:
UNI EN 22768-1
Codice
Descrizione:
Scala
Mod.
Approvato:
Disegnato:
Data:
Scostamenti limite Toll.Forma:
CLASSE:
CLASSE:
UNI EN 22768-2
m
K
1,05
26,7
0,33
8,5
2,57
65,3
2,95
75
2,25
57,2
0,17
R4,25
2,56
65
0,16
4,1
0,23
5,9
2,95
75
1,13
28,7
0,87
22,2
1,81
46
2,59
65,8
Hex.
1,26
32
1-1/16" -12 UNF-2A
0,93
23,5
1,39
35,4
1
2
1,42
36
2,95
75
1,57
40
Foglio1
Foglio
Note:
A3
Questo documento è di propietà Eltfluid non è quindi possibile riprodurre dati o specifiche senza il suo consenso scritto.Eltfluid si riserva anche il diritto di poter in qualunque caso apportare modifiche ai dati sopra citati.
La società propietaria tutela i propri diritti a rigore di legge.
+/- 0.5
+/- 0.3
+/- 0.2
+/- 0.1
>120 <=400
>30 <=120
>6 <=30
Fino a 6
Scostamenti limite ammessi per dimensioni
lineari, esclusi smussi e raccordi per
eliminazione spigoli.
Valori in mm
Data:
-
1:1
-
- -
0
Scostamenti limite per dim.lineari:
UNI EN 22768-1
Codice
Descrizione:
Scala
Mod.
Approvato:
Disegnato:
Data:
Scostamenti limite Toll.Forma:
CLASSE:
CLASSE:
UNI EN 22768-2
m
K
Description
Electric cartridge valve on/off designed to hold the load or block flow at
high pressure application, where low leakage is requested.
Operation mode
COIL NOT POWERED: the valve allows flow from 2 to 1.
COIL POWERED: the valve in closed position blocks the flow from 2 to 1.
GENERAL DATA
Weight without coil: 0,26 Kg (0,58 lbs).
Ambient temperature range: -30 C° a 60 C° with standard seals (NBR).
Max. proof pressure: 420 bar (6.090 psi).
Flow Max: 150 l/min
Cartridge materials: high strength steel, internal parts hardened and
grinding.
1
2
0
5
10
15
0 30 60 90 120 150
0
50
100
150
200
0 10 20 30 40
Flow from 2 in 1
Pressure bar/psi
Flow lpm/gpm
TECHNICAL DATA
HYDRAULIC
Max. working pressure: 350 bar (5.075 psi)
Flow rate: min 5 l/min (1,3 gpm)
max 150 l/min (40 gpm)
Fluid:
Viscosity:
Mineral based oil
From 15cSt to 250 cSt
Leakage: 0,25 cc/min (5 drops/min)
P max. 350 bar (5.075 psi)
Standard seals: O-ring NBR Seals Polyurethane
Cavity: SCN1220
Installation torque: 60 N/m
Coil nut torque: 2 N/m
Max contamination level: NAS 8 ISO 4406 19/17/14
Fluid temperature range: From -20 to +80 C°
Fatigue cycle life: 1.000.000 cycle at 350 bar
Seal kit std.: K122N00
ELECTRIC
Type of voltage: DC
Insulation index: H
Nominal voltage: +/- 10 %
Power at 20 C°: 22 W
ED*: 100% with ambient temperature
range -20 C° +40 C°
Coil code:
(see page 9.012)
S130-22P
*Note: For temperature or special conditions contact our sales department.
Electric valve
Solenoid valve 2 ways 2 positions,
poppet pilot operated, normally open.
091.1
FE 0212 IR 00
Elt Fluid s.r.l
Via Ganapini,15/2
Loc. Felina 42035
Reggio Emilia (RE) ITALY
mail: info@eltfluid.com
P.IVA/C.F 02573790355
Inches
Millimeters
Voltage
Seals
Connector
Options*
Housing size ports
Material std. housing
-
-
*Note: Information about manual
override is available at page S.011
Ordering code
SV- Screw in
STANDARD HOUSING
Ordering code: See page 9.152
Material*: Aluminium/Steel
Max working pressure for aluminum body: 210 bar
Max working pressure for steel body: 350 bar
*Note: To correctly select the material, in relation to application, see page S.023.
1.
None (std. NBR + Polyurethane)
V- Viton
Y- Polyurethane
DN- Din
DU- Deutsch
AM- Amp Junior
14- Vdc
24- Vdc
12- Vdc
None (std. without coil)
A- Aluminium
S- Steel
E12N-21
4B- 1/2” BSP
5B- 3/4” BSP
4S- SAE 10
5S- SAE 12
E12N-21
Dimensions
None (std. without override)
None (std. only cartridge)
P- Push
PT- Push and twist
091.2
1,05
26,7
0,33
8,5
2,57
65,3
2,95
75
2,25
57,2
0,17
R4,25
2,56
65
0,16
4,1
0,23
5,9
2,95
75
1,13
28,7
0,87
22,2
1,81
46
2,59
65,8
Hex.
1,26
32
1-1/16" -12 UNF-2A
0,93
23,5
1,39
35,4
1
2
1,42
36
2,95
75
1,57
40
Foglio1
Foglio
Note:
A3
Questo documento è di propietà Eltfluid non è quindi possibile riprodurre dati o specifiche senza il suo consenso scritto.Eltfluid si riserva anche il diritto di poter in qualunque caso apportare modifiche ai dati sopra citati.
La società propietaria tutela i propri diritti a rigore di legge.
+/- 0.5
+/- 0.3
+/- 0.2
+/- 0.1
>120 <=400
>30 <=120
>6 <=30
Fino a 6
Scostamenti limite ammessi per dimensioni
lineari, esclusi smussi e raccordi per
eliminazione spigoli.
Valori in mm
Data:
-
1:1
-
- -
0
Scostamenti limite per dim.lineari:
UNI EN 22768-1
Codice
Descrizione:
Scala
Mod.
Approvato:
Disegnato:
Data:
Scostamenti limite Toll.Forma:
CLASSE:
CLASSE:
UNI EN 22768-2
m
K
1,05
26,7
0,33
8,5
2,57
65,3
2,95
75
2,25
57,2
0,17
R4,25
2,56
65
0,16
4,1
0,23
5,9
2,95
75
1,13
28,7
0,87
22,2
1,81
46
2,59
65,8
Hex.
1,26
32
1-1/16" -12 UNF-2A
0,93
23,5
1,39
35,4
1
2
1,42
36
2,95
75
1,57
40
Foglio1
Foglio
Note:
A3
Questo documento è di propietà Eltfluid non è quindi possibile riprodurre dati o specifiche senza il suo consenso scritto.Eltfluid si riserva anche il diritto di poter in qualunque caso apportare modifiche ai dati sopra citati.
La società propietaria tutela i propri diritti a rigore di legge.
+/- 0.5
+/- 0.3
+/- 0.2
+/- 0.1
>120 <=400
>30 <=120
>6 <=30
Fino a 6
Scostamenti limite ammessi per dimensioni
lineari, esclusi smussi e raccordi per
eliminazione spigoli.
Valori in mm
Data:
-
1:1
-
- -
0
Scostamenti limite per dim.lineari:
UNI EN 22768-1
Codice
Descrizione:
Scala
Mod.
Approvato:
Disegnato:
Data:
Scostamenti limite Toll.Forma:
CLASSE:
CLASSE:
UNI EN 22768-2
m
K
1,05
26,7
0,33
8,5
2,57
65,3
2,95
75
2,25
57,2
0,17
R4,25
2,56
65
0,16
4,1
0,23
5,9
2,95
75
1,13
28,7
0,87
22,2
1,81
46
2,59
65,8
Hex.
1,26
32
1-1/16" -12 UNF-2A
0,93
23,5
1,39
35,4
1
2
1,42
36
2,95
75
1,57
40
Foglio1
Foglio
Note:
A3
Questo documento è di propietà Eltfluid non è quindi possibile riprodurre dati o specifiche senza il suo consenso scritto.Eltfluid si riserva anche il diritto di poter in qualunque caso apportare modifiche ai dati sopra citati.
La società propietaria tutela i propri diritti a rigore di legge.
+/- 0.5
+/- 0.3
+/- 0.2
+/- 0.1
>120 <=400
>30 <=120
>6 <=30
Fino a 6
Scostamenti limite ammessi per dimensioni
lineari, esclusi smussi e raccordi per
eliminazione spigoli.
Valori in mm
Data:
-
1:1
-
- -
0
Scostamenti limite per dim.lineari:
UNI EN 22768-1
Codice
Descrizione:
Scala
Mod.
Approvato:
Disegnato:
Data:
Scostamenti limite Toll.Forma:
CLASSE:
CLASSE:
UNI EN 22768-2
m
K